Medium Voltage Switchgear

In medium voltage switchgear range most widely accepted technology is Vacuum in compare to SF6. In most of the cases medium voltage breakers are used in the distribution segment & located in populated areas. Vacuum technology is the only solution for medium voltage application SF6 gas is very hazardous for human & therefore for remote application SF6 technology is used. SF6 technology is commonly used in high voltage application I,e above 66KV class.

Vacuum Circuit Breaker

MVS - 1
  • Encolsure - Metal cladfully insulated, IP4X protection
  • Cubicle - all HV compartments - internal arc tested
  • Vacuum Interrupter - Trefoil arrangement - very low width possible.
  • Integral fault make earthing through Circuit Breaker - reclocation


  • Rated Voltage - Upto 12kV
    Rated Current -1250A, Busbar 2000A
    Fault level - 26.3kA for 3 Secs.

Flame Proof Circuit Breakers

MVS - 2
  • For underground mining and inflammable environment
  • Pedastal mounting and transformer mounting arrangement
  • Switchboard formation


  • Rated Voltage - 3.6kV
    Rated Current - 400A
    Short Circuit Current - 13.1kA

Vacuum Circuit Breaker

MVS - 3
  • Enclosure - Metal clad fully insulated, IP 55 protection
  • Cubicle - all HV compartments - internal arc tested
  • Circuit Breaker - Horizontal isolation and draw out
  • Earthing - fault make, PT interlocked earth switch.
  • 100% insulated design - no access to live parts.
  • Modular duplicate busbar arrangement


  • Rated Voltage - Upto 12kV
    Rated Current - 3150A
    Fault level - 44kA for 3 Secs

Vacuum Contactor panel (Fixed Type)

MVS - 4
  • Fixed type contactor panel engineered for multiple applications
  • Latch in mechanism, fuse trip arrangement - optional
  • Mechanical interlock between two contactors - special feature
  • Suitable for SD/AT/Synchronous motor starting


  • Rated Voltage - 7.2 kV
    AC4 Duty - 400 A
    Application - Engineered
    Short time rating - 31.5kA - 3 Sec

Vacuum Contactor Panel (Draw out Type)

MVS - 5
  • Vacuum Contactor mounted on draw out truck
  • Contactor Panel & CB Panel completely matched in Switchboard
  • All features are identical for operation in VCB switchgear panel


  • Rated Voltage - 7.2 kV
    AC4 Duty - 400A
    Application - DOL
    Short time rating - 44kA - 3 Sec

33 kV Indoor Switchgear

MVS - 6
  • Indoor 33KV vacuum circuit breaker
  • Internal ARC tested cubicle


  • Rated Voltage - 24/36kV
    Rated Current - 2500A
    Fault level - 31.5kA

33KV Outdoor VCB in Dead Tank Design

MVS - 7
  • Dead tank, structure mounted, outdoor VCB
  • Bushing mounted CT
  • Arc interrupted inside Vacuum Interrupter and SF6 gas is used for additional insulation


  • Rated Voltage - 36kA
    Rated Current - 2000A
    Fault level - 25kA - 3 Sec

33KV Outdoor Porcelin Clad Vacuum Switchgear

MVS - 8
  • Global product - tested at KEMA
  • Tested for environmental conditions in UK
  • Mechanism designed for 30,000 operations and conveniently located
  • All - weather proof surface treatment / painting.
  • Option for higher phase to phase and phase to earth clearance.


  • Rated Voltage - 36kV
    Rated Current - 2000A
    Fault level - 25kA - 3 Secs

12KV Outdoor Porcelin Clad Vacuum Switchgear

MVS - 9
  • Global product - tested at KEMA
  • Tested for environmental conditions in UK
  • Mechanism designed for 30,000 operations and conveniently located
  • All - weather proof surface treatment / painting.
  • Option for higher phase to phase and phase to earth clearance.


  • Rated Voltage - 12kV
    Rated Current - 1600A
    Fault level - 25.3kA - 3 Secs

Loco Head VCB

MVS - 10
  • Operating in field more than 20 years, more than 1,500 VCBs in operation
  • Single Interrupter design - tested in KEMA


  • Rated Voltage - 25kV
    Rated Current - 600A
    Short Circuit Current - 10kA

Loco Head VCB

MVS - 11
  • Operating in field more than 15 years, more than 2,000 VCBs in operation
  • Single Interrupter design - tested in KEMA


  • Rated Voltage - 25kV
    Rated Current - 1000A
    Short Circuit Current - 16kA