Vacuum Circuit Breaker |
MVS - 1
|
- Encolsure - Metal cladfully insulated, IP4X protection
- Cubicle - all HV compartments - internal arc tested
- Vacuum Interrupter - Trefoil arrangement - very low width possible.
- Integral fault make earthing through Circuit Breaker - reclocation
Rated Voltage - Upto 12kV
Rated Current -1250A, Busbar 2000A
Fault level - 26.3kA for 3 Secs.
|
Flame Proof Circuit Breakers |
MVS - 2
|
- For underground mining and inflammable environment
- Pedastal mounting and transformer mounting arrangement
- Switchboard formation
Rated Voltage - 3.6kV
Rated Current - 400A
Short Circuit Current - 13.1kA
|
Vacuum Circuit Breaker |
MVS - 3
|
- Enclosure - Metal clad fully insulated, IP 55 protection
- Cubicle - all HV compartments - internal arc tested
- Circuit Breaker - Horizontal isolation and draw out
- Earthing - fault make, PT interlocked earth switch.
- 100% insulated design - no access to live parts.
- Modular duplicate busbar arrangement
Rated Voltage - Upto 12kV
Rated Current - 3150A
Fault level - 44kA for 3 Secs
|
Vacuum Contactor panel (Fixed Type) |
MVS - 4
|
- Fixed type contactor panel engineered for multiple applications
- Latch in mechanism, fuse trip arrangement - optional
- Mechanical interlock between two contactors - special feature
- Suitable for SD/AT/Synchronous motor starting
Rated Voltage - 7.2 kV
AC4 Duty - 400 A
Application - Engineered
Short time rating - 31.5kA - 3 Sec
|
Vacuum Contactor Panel (Draw out Type) |
MVS - 5
|
- Vacuum Contactor mounted on draw out truck
- Contactor Panel & CB Panel completely matched in Switchboard
- All features are identical for operation in VCB switchgear panel
Rated Voltage - 7.2 kV
AC4 Duty - 400A
Application - DOL
Short time rating - 44kA - 3 Sec
|
33 kV Indoor Switchgear |
MVS - 6
|
- Indoor 33KV vacuum circuit breaker
- Internal ARC tested cubicle
Rated Voltage - 24/36kV
Rated Current - 2500A
Fault level - 31.5kA
|
33KV Outdoor VCB in Dead Tank Design |
MVS - 7
|
- Dead tank, structure mounted, outdoor VCB
- Bushing mounted CT
- Arc interrupted inside Vacuum Interrupter and SF6 gas is used for additional insulation
Rated Voltage - 36kA
Rated Current - 2000A
Fault level - 25kA - 3 Sec
|
33KV Outdoor Porcelin Clad Vacuum Switchgear |
MVS - 8
|
- Global product - tested at KEMA
- Tested for environmental conditions in UK
- Mechanism designed for 30,000 operations and conveniently located
- All - weather proof surface treatment / painting.
- Option for higher phase to phase and phase to earth clearance.
Rated Voltage - 36kV
Rated Current - 2000A
Fault level - 25kA - 3 Secs
|
12KV Outdoor Porcelin Clad Vacuum Switchgear |
MVS - 9
|
- Global product - tested at KEMA
- Tested for environmental conditions in UK
- Mechanism designed for 30,000 operations and conveniently located
- All - weather proof surface treatment / painting.
- Option for higher phase to phase and phase to earth clearance.
Rated Voltage - 12kV
Rated Current - 1600A
Fault level - 25.3kA - 3 Secs
|
Loco Head VCB |
MVS - 10
|
- Operating in field more than 20 years, more than 1,500 VCBs in operation
- Single Interrupter design - tested in KEMA
Rated Voltage - 25kV
Rated Current - 600A
Short Circuit Current - 10kA
|
Loco Head VCB |
MVS - 11
|
- Operating in field more than 15 years, more than 2,000 VCBs in operation
- Single Interrupter design - tested in KEMA
Rated Voltage - 25kV
Rated Current - 1000A
Short Circuit Current - 16kA
|